Auto Soportado Tendido Aereo 24hilos Span100
GL FiberĀ® single sheath fiber optic cable is designed for outside plant aerial and duct applications in local and campus network loop architectures. Mini-Span includes fiber counts up to 144 optical fibers and any type of combination of single-mode and laser-optimized multimode fibers with the cable.
Fiber counts: up to 144core
Fiber type: Single mode fiber G652.D
Central Strength Member: FRP
Additional Strength Member: Kevlar Aramid Yarn
Outer Jacket: MDPE/ HDPE
Application: Self-supporting overhead laying, Electric no power off installation
Moisture Resistance: Water-blocking Yarn & Water-blocking Tape
Span customized: 80/100/120/150/200/250m etc.
Structure Design:
Main Feature:
1. Suitable for use on distribution and high voltage transmissionĀ lines with mini spans or self supporting installation forĀ telecommunicationļ¼
2. Track -Resistant outer jacket available for the high voltage (ā„35KV); HDPEĀ outer jacket available for the high voltage (ā¤35KV)ļ¼
3. Excellent AT performance. The maximum inductive at the operating point of AT jacket can reach 25kV.
4. Gel-Filled buffer tubes are S-Z stranded;
5. Can be installed without shutting off the power.
6. Light weight and small diameter reducing the load caused by ice and wind and the load on towers and backprops.
7. Good performance of tensile strength and temperature.
8. The design life span is over 30 years.
Standards:
GL FIBER’s ADSS Fiber Cable complies withĀ IEC 60794-4, IEC 60793, TIA/EIA 598 A standards.
Advantages of GL ADSS Optical Fiber Cable:
1.Good aramid yarn have excellent tensile performance;
2.Fast delivery, 200km ADSS cable regular production time about 10 days;
3.Can using glass yarn instead of aramid to anti rodent.
Colors -12 Chromatographyļ¼
Ā Optical Fiber Characteristics:
|
Optical Characteristics |
|||||||||||||||||||
| Ā | Ā | Ā | Ā | G.652.D | G.655 | 50/125um | 62.5/125um | ||||||||||||
| Attenuation | @850nm | – | – | ā¤3.0 dB/km | ā¤3.0 dB/km | ||||||||||||||
| @1300nm | – | – | ā¤1.0 dB/km | ā¤1.0 dB/km | |||||||||||||||
| @1310nm | ā¤0.36 dB/km | ā¤0.40 dB/km | – | – | |||||||||||||||
| @1550nm | ā¤0.22 dB/km | ā¤0.23 dB/km | – | – | |||||||||||||||
| Bandwidth | @850nm | – | – | ā„500 MHz Ā· km | ā„200 MHz Ā· km | ||||||||||||||
| @1300nm | – | – | ā„1000 MHz Ā· km | ā„600 MHz Ā· km | |||||||||||||||
| Polarization mode | Individual ļ¬ber | ā¤0.20 ps/ākm | ā¤0.20 ps/ākm | – | – | ||||||||||||||
| Design link value (M=20,Q=0.01%) | ā¤0.10 ps/ākm | ā¤0.10 ps/ākm | Ā | ||||||||||||||||
Typical Technical Parameter of 24 core ADSS Cable:
| Item | Value | |||
| Span | 100m | |||
| Fiber Counts | 12 | 24 | 48 | 96 |
| Tubes | 2 | 4 | 4 | 8 |
| Tube Material | PBT | |||
| Filling Rope | 4 | 2 | 1 | 0 |
| Fiber Counts/ Tube | 6 | 6 | 12 | 12 |
| Fiber Identification | Blue Orange Green Brown Grey White | Blue Orange Green Brown Grey White | Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua | Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua |
| OD of Tube | 1.8±0.1 mm | 1.8±0.1 mm | 2.1±0.1 mm | 2.1±0.1 mm |
| Thickness of Tube | 0.30±0.05 mm | 0.30±0.05 mm | 0.32±0.05 mm | 0.32±0.05 mm |
| Color of Tube | Blue Orange | Blue Orange Green Brown | Ā Blue Orange Green Brown | Blue Orange Green Brown Grey White Red Black Ā |
| FRP | 1.8 mm | 1.8 mm | 1.8mm | 2.5 mm |
| PE Coated FRP | – | – | – | 3.5 mm |
| Water Blocking Material | Water Blocking Yarn and Water Blocking Tape | |||
| Peripheral Strength Member | Aramid Yarn | |||
| Ripcord | Red Polyester *1 | |||
| Thickness of Sheath | Ā Nominal 1.60 mm | |||
| Sheath Material | HDPE | |||
| OD of Cable | 9.0±0.3 mm | 9.0±0.3 mm | 9.6±0.3 mm | 11.4±0.3 mm |
| Cable Weight | 65 kg/km | 65 kg/km | 75 kg/km | 105 kg/km |
Remarks:
Detail requirements need to be sent to us for cable design and price calculation. Below requirements are a must:
A, Power transmission line voltage level
B, fiber count
C, Span or tensile strength
D, weather conditions
How to Ensure the Quality and Performance of Your Fiber Optic Cable?
We control the products quality from the raw material to the finish produts All the raw material should be tested to match the Rohs standard when they arrived at our manufacture.We control the quality during the producing process by advanced technology and equipments. We test the finished products according to the test standard. Approved by various professional optical and communication product institution , GL also conductĀ various in-house testing in its own Laboratory and Test Center. We also conduct test with specialĀ arrangement with the Chinese Government Ministry of Quality Supervision & Inspection Center ofĀ Optical Communication Products(QSICO).Ā
Quality Control – Test Equipment and Standard:
Feedback:Ā In order to meet the worldās highest quality standards, we continuously monitor feedback from our customers. For comments and suggestions, please contact us, Email: [emailĀ protected].
ADSS Single Jacket All-Dielectric Self-Supporting Fiber optic cable is idea for installation in distribution as well as transmission envirline installations are required as its name indicates, there is no support or messenger wire required, so installation is achieved in a single pass.Structural features:Single layer ,Loose tube stranding, Non-metal strength member, Half dry water-blocking, Aramid yarn strength member, PE outer jacket. Includes 2 core, 4 core, 6 core, 8 core, 12 core, 16 core, 24 core, 36 core, 48 core, 96 core, up to 144 core.
GL FiberāsĀ single jackets ADSS fiber optic cable complies with standardĀ IECĀ 60794-4ćĀ IECĀ 60793ćTIA/EIAĀ 598Ā A.
Fiber Optic Characteristics:
| G.652D | 50/125μm | 62.5/125μm | ||
| AttenuationĀ (+20) | @850nm | Ā | ā¤3.0Ā dB/km | ā¤3.0Ā dB/km |
| @1300nm | Ā | ā¤1.0Ā dB/km | ā¤1.0Ā dB/km | |
| @1310nm | ā¤0.36Ā dB/km | Ā | Ā | |
| @1550nm | ā¤0.22Ā dB/km | Ā | Ā | |
| BandwidthĀ (ClassĀ A) | @850nm | Ā | ā„500Ā MHzĀ·km | ā„200Ā MHzĀ·km |
| @1300nm | Ā | ā„1000Ā MHzĀ·km | ā„600Ā MHzĀ·km | |
| Numerical Aperture |  | 0.200±0.015NA | 0.275±0.015NA | |
| CableĀ Cut-offĀ WavelengthĀ Ī»cc | ā¤1260nm | Ā |
2-144 Core Single Jackets ADSS Cable Specifications:
|
Cable fiber count
|
/
|
2~30
|
32~60
|
62~72
|
96
|
144
|
|
|
Structure
|
/
|
1+5
|
1+5
|
1+6
|
1+8
|
1+12
|
|
|
Fiber style
|
/
|
G.652D
|
|||||
|
Central strength member
|
material
|
mm
|
FRP
|
||||
|
Diameter (average)
|
1.5
|
1.5
|
2.1
|
2.1
|
2.1
|
||
|
Loose Tube
|
Material
|
mm
|
PBT
|
||||
|
Diameter (average)
|
1.8
|
2.1
|
2.1
|
2.1
|
2.1
|
||
|
Thickness(average)
|
0.32
|
0.35
|
0.35
|
0.35
|
0.35
|
||
|
Max fiber/loose tube
|
6
|
12
|
12
|
12
|
12
|
||
|
Tubes color
|
Full color identification
|
||||||
|
Fiber excess length
|
%
|
0.7~0.8
|
|||||
|
Water resistance
|
Material
|
/
|
Cable jelly + water resistant layer
|
||||
|
Non-metallic strengthen components
|
Material
|
/
|
Aramid Yarn
|
||||
|
Outer sheath
|
material
|
mm
|
MDPE
|
||||
|
Outer sheath
|
1.8mm
|
||||||
|
Cable diameter(average)
|
mm
|
9.6
|
10.2
|
10.8
|
12.1
|
15
|
|
|
Cable weight (Approximate)
|
kg/km
|
70
|
80
|
90
|
105
|
125
|
|
|
Cable Sectional area
|
mm2
|
72.38
|
81.72
|
91.61
|
115
|
176.7
|
|
|
Attenuation coefficient(Max)
|
1310nm
|
dB/km
|
0.35
|
||||
|
1550nm
|
0.21
|
||||||
|
Rated Tensile Strength(RTS)
|
kn
|
5.8
|
|||||
|
Max allowed tension( MAT)
|
kn
|
2.2
|
|||||
|
Annual average operating tension (EDS)
|
kn
|
3.0
|
|||||
|
Youngās modulus
|
kn/mm2
|
7.6
|
|||||
|
Coefficient of thermal expansion
|
10-6/ā
|
9.3
|
|||||
|
Crush resistance
|
Long term
|
N/100mm
|
1100
|
||||
|
Short term
|
2200
|
||||||
|
Permission Bent Radius
|
static
|
mm
|
15 of OD
|
||||
|
dynamic
|
20 of OD
|
||||||
|
Temperature
|
When laying
|
ā
|
-20~+60
|
||||
|
Storage and transportation
|
-40~+70
|
||||||
|
runing
|
-40~+70
|
||||||
|
Scope of application
|
Suitable for voltage level under 110kV, wind speed below 25m/s, icing 5mm
|
||||||
|
Cable Marks
|
Company Name ADSS-ĆĆB1-PE-100M DL/T 788-2001 ĆĆĆĆM Year
ļ¼Or at customerās requestļ¼ |
||||||
NoteĀ :Only s part of ADSS cable are listed in the table. ADSS cables with other spans can be inquired from GL Fiber directly.
Specifications in the table are got on condition that there is no height difference and the installation sag is 1%.
Fiber count is 2 to 144. The identification of fibers complies with the national standard.
This datasheer can only be a rerence, nor a supplement to the contract. Please contact our sales people for more detailed information.