ADSS Fiber Optic Cable 60 Core 200m Span Single-Mode G652D
JQ Fiber ADSS 60 Core 200m Span Single-Mode G652D Fiber Optic Cable is designed for outside plant aerial and duct applications in local and campus network loop architectures. Mini-Span includes fiber counts up to 144 optical fibers and any type of combination of single-mode and laser-optimized multimode fibers with the cable.
Model: JQ Fiber ADSS Cable, Single jacket, 2~144F;
Fiber Type: ITU G652D, G657A, OM1, OM2, OM3, OM4;
Fiber counts: 2-144 core is available;
Span: 50M ~200M.
Standard: IEC 60794-4、 IEC 60793、TIA/EIA 598 A ;
Structure Design:
Main Feature:
1. Suitable for use on distribution and high voltage transmission lines with mini spans or self supporting installation for telecommunication;
2. Track -Resistant outer jacket available for the high voltage (≥35KV); HDPE outer jacket available for the high voltage (≤35KV);
3. Excellent AT performance. The maximum inductive at the operating point of AT jacket can reach 25kV.
4. Gel-Filled buffer tubes are S-Z stranded;
5. Can be installed without shutting off the power.
6. Light weight and small diameter reducing the load caused by ice and wind and the load on towers and backprops.
7. Good performance of tensile strength and temperature.
8. The design life span is over 30 years.
Standards:
JQ Fiber’s ADSS Fiber Optical Cable complies with IEC 60794-4, IEC 60793, TIA/EIA 598 A standards.
Advantages of JQ Fiber’ ADSS Optical Fiber Cable:
1.Good aramid yarn have excellent tensile performance;
2.Fast delivery, 200km ADSS cable regular production time about 10 days;
3.Can using glass yarn instead of aramid to anti rodent.
Colors -12 Chromatography:
Fiber Optic Characteristics:
| G.652 | G.655 | 50/125μm | 62.5/125μm | ||
| Attenuation (+20℃) |
@850nm | ≤3.0 dB/km | ≤3.0 dB/km | ||
| @1300nm | ≤1.0 dB/km | ≤1.0 dB/km | |||
| @1310nm | ≤0.00 dB/km | ≤0.00dB/km | |||
| @1550nm | ≤0.00 dB/km | ≤0.00dB/km | |||
| Bandwidth(Class A) | @850nm | ≥500 MHz·km | ≥200 MHz·km | ||
| @1300nm | ≥500 MHz·km | ≥500 MHz·km | |||
| Numerical aperture | 0.200±0.015NA | 0.275±0.015NA | |||
| Cable Cutoff Wavelength | ≤1260nm | ≤1480nm | |||
Typical Technical Parameter of ADSS Cable:
| Part code | ADSS-DJ-120M-48F | |
| Number of Fibers | Unit | 12core |
| Number of fiber in tube | Nos | 12 |
| Number of loose tube | Nos | 4 |
| Number of dummy filler | Nos | 1 or 2 |
| Central strength member | Material | FRP |
| Loose tube | Material | PBT |
| peripheral strength member | Material | Aramid yarn |
| Water block | Material | Water swellable tape and water block yarn |
| Outer sheath | Material | HDPE |
| Cable nominal Diameter | MM ±0.2 | 10.4 |
| Cable nominal weight | Kg/Km ±5 | 85 |
| Max. Allowable tension Load | N | 2500 |
| Span | Suitable for 120 span | |
| Max. crush resistance | N | 2000 (Short term) / 1000 (Long term) |
| Min. bending radius | At full load 20 x Cable OD (including poles) At no load 15 x Cable OD | |
| Temperature range | Installation -0 -> +50 Operation -10 -> +70 | |
Remarks:
Detail requirements need to be sent to us for ADSS cable design and price calculation. Below requirements are a must:
A, Power transmission line voltage level
B, fiber count
C, Span or tensile strength
D, weather conditions
How to Ensure the Quality and Performance of Your Fiber Optic Cable?
We control the products quality from the raw material to the finish produts All the raw material should be tested to match the Rohs standard when they arrived at our manufacture.We control the quality during the producing process by advanced technology and equipments. We test the finished products according to the test standard. Approved by various professional optical and communication product institution , JQ also conduct various in-house testing in its own Laboratory and Test Center. We also conduct test with special arrangement with the Chinese Government Ministry of Quality Supervision & Inspection Center of Optical Communication Products(QSICO).
ADSS Single Jacket All-Dielectric Self-Supporting Fiber optic cable is idea for installation in distribution as well as transmission envirline installations are required as its name indicates, there is no support or messenger wire required, so installation is achieved in a single pass.Structural features:Single layer ,Loose tube stranding, Non-metal strength member, Half dry water-blocking, Aramid yarn strength member, PE outer jacket. Includes 2 core, 4 core, 6 core, 8 core, 12 core, 16 core, 24 core, 36 core, 48 core, 96 core, up to 144 core.
2-144 Core Single Jackets ADSS Cable Specifications:
|
Cable fiber count
|
/
|
2~30
|
32~60
|
62~72
|
96
|
144
|
|
|
Structure
|
/
|
1+5
|
1+5
|
1+6
|
1+8
|
1+12
|
|
|
Fiber style
|
/
|
G.652D
|
|||||
|
Central strength member
|
material
|
mm
|
FRP
|
||||
|
Diameter (average)
|
1.5
|
1.5
|
2.1
|
2.1
|
2.1
|
||
|
Loose Tube
|
Material
|
mm
|
PBT
|
||||
|
Diameter (average)
|
1.8
|
2.1
|
2.1
|
2.1
|
2.1
|
||
|
Thickness(average)
|
0.32
|
0.35
|
0.35
|
0.35
|
0.35
|
||
|
Max fiber/loose tube
|
6
|
12
|
12
|
12
|
12
|
||
|
Tubes color
|
Full color identification
|
||||||
|
Fiber excess length
|
%
|
0.7~0.8
|
|||||
|
Water resistance
|
Material
|
/
|
Cable jelly + water resistant layer
|
||||
|
Non-metallic strengthen components
|
Material
|
/
|
Aramid Yarn
|
||||
|
Outer sheath
|
material
|
mm
|
MDPE
|
||||
|
Outer sheath
|
1.8mm
|
||||||
|
Cable diameter(average)
|
mm
|
9.6
|
10.2
|
10.8
|
12.1
|
15
|
|
|
Cable weight (Approximate)
|
kg/km
|
70
|
80
|
90
|
105
|
125
|
|
|
Cable Sectional area
|
mm2
|
72.38
|
81.72
|
91.61
|
115
|
176.7
|
|
|
Attenuation coefficient(Max)
|
1310nm
|
dB/km
|
0.35
|
||||
|
1550nm
|
0.21
|
||||||
|
Rated Tensile Strength(RTS)
|
kn
|
5.8
|
|||||
|
Max allowed tension( MAT)
|
kn
|
2.2
|
|||||
|
Annual average operating tension (EDS)
|
kn
|
3.0
|
|||||
|
Young’s modulus
|
kn/mm2
|
7.6
|
|||||
|
Coefficient of thermal expansion
|
10-6/℃
|
9.3
|
|||||
|
Crush resistance
|
Long term
|
N/100mm
|
1100
|
||||
|
Short term
|
2200
|
||||||
|
Permission Bent Radius
|
static
|
mm
|
15 of OD
|
||||
|
dynamic
|
20 of OD
|
||||||
|
Temperature
|
When laying
|
℃
|
-20~+60
|
||||
|
Storage and transportation
|
-40~+70
|
||||||
|
runing
|
-40~+70
|
||||||
|
Scope of application
|
Suitable for voltage level under 110kV, wind speed below 25m/s, icing 5mm
|
||||||
|
Cable Marks
|
Company Name ADSS-××B1-PE-100M DL/T 788-2001 ××××M Year
(Or at customer’s request) |
||||||
What will affect the price of ADSS?
All Dielectric Self Supporting ADSS Cable is laid next to the power cable, so the material of the outer sheath needs to be designed according to the voltage. If it exceeds 110KV, it needs to use AT material, and if it is less than 110KV, it will use PE material.
The wind speed at the laying site, the thickness of the ice, the average temperature, and the most important span (the span refers to the distance between two utility poles) will all affect the tensile strength of the ADSS. If the tensile strength is not enough, the optical cable will be easily to be pulled off.
Finally, the customer should inform the number of fibers of the required ADSS cable, so that our engineer can design the ADSS according to the requirements.
| Fiber Type | □ Single Mode B1-G.652D-9/125mm
□ Single Mode B4-G.655
□ Multi Model A1a-50/125mm
□ Multi Model A1b-62.5/125mm
□ Or Customer Specified
|
|
| Fiber Cores | □ 2Cores
□ 4Cores
□ 6Cores
□ 8Cores
□ 12Cores
□ 24Cores
□ 36Cores
□ 48Cores
□ 72Cores
□ 96Cores
□ 144Cores
□ Or Customer Specified
|
|
| Installation Span | □ 50Meter
□ 80Meter
□ 100Meter
□ 120Meter
□ 150Meter
□ 200Meter
□ 250Meter
□ 300Meter
□ 400Meter
□ 600Meter
□ Or Customer Specified
|
|
| Max. Allowable Tension | □ 4KN
□ 6KN
□ 9KN
□ 12KN
□ 15KN
□ 18KN
□ 19KN
□ 21KN
□ 24KN
□ 26KN
□ 27KN
□ Or Customer Specified
|
|
| Sheath / Jacket (Materials) | □ PE
□ AT
|
Voltage grade: <110KV
Voltage grade: >110KV |
| Max. Wind Speed | How Many Meters Per Second | |
| Max. thickness of ice coverage | Winter Max. thickness of ice coverage | |
| Max., Min., Avg. temperature | -℃~+℃ |