6 Core ADSS Fiber Optical Cable Single Jacket 100M SPAN SM G652D
JQ Mini-Span All-Dielectric Self Supporting (ADSS) fiber optic cable is designed for outside plant aerial and duct applications in local and campus network loop architectures. Mini-Span includes fiber counts up to 144 optical fibers and any type of combination of single-mode and laser-optimized multimode fibers with the cable.
Model: 6 Core Single Jacket ADSS Cable;
Fiber Type: ITU G652D, G657A, OM1, OM2, OM3, OM4;
Span: 50M ~150M;
Standard: IEC 60794-4、 IEC 60793、TIA/EIA 598 A;
Certification: ISO9001
Structure Design:
Main Features:
1. Suitable for use on distribution and high voltage transmission lines with mini spans or self supporting installation for telecommunication;
2. Track -Resistant outer jacket available for the high voltage (≥35KV); HDPE outer jacket available for the high voltage (≤35KV);
3. Excellent AT performance. The maximum inductive at the operating point of AT jacket can reach 25kV.
4. Gel-Filled buffer tubes are S-Z stranded;
5. Can be installed without shutting off the power.
6. Light weight and small diameter reducing the load caused by ice and wind and the load on towers and backprops.
7. Good performance of tensile strength and temperature.
8. The design life span is over 30 years.
Standards:
JQ Fiber’s ADSS Fiber Optical Cable complies with IEC 60794-4, IEC 60793, TIA/EIA 598 A standards.
Advantages of ADSS Optical Fiber Cable:
1.Good aramid yarn have excellent tensile performance;
2.Fast delivery, 200km ADSS cable regular production time about 10 days;
3.Can using glass yarn instead of aramid to anti rodent.
Colors -12 Chromatography:
Fiber Optic Characteristics:
| G.652 | G.655 | 50/125μm | 62.5/125μm | ||
| Attenuation (+20℃) |
@850nm | ≤3.0 dB/km | ≤3.0 dB/km | ||
| @1300nm | ≤1.0 dB/km | ≤1.0 dB/km | |||
| @1310nm | ≤0.00 dB/km | ≤0.00dB/km | |||
| @1550nm | ≤0.00 dB/km | ≤0.00dB/km | |||
| Bandwidth(Class A) | @850nm | ≥500 MHz·km | ≥200 MHz·km | ||
| @1300nm | ≥500 MHz·km | ≥500 MHz·km | |||
| Numerical aperture | 0.200±0.015NA | 0.275±0.015NA | |||
| Cable Cutoff Wavelength | ≤1260nm | ≤1480nm | |||
Typical Technical Parameter of ADSS Cable:
| Technical Data | |||||||||||||||||||
| Item | Contents | Fibers | |||||||||||||||||
| Fibre Count | 6|12|24 | 48 | 72 | 96 | 144 | 288 | |||||||||||||
| Loose Tube | Tubes* Fbres/Tube | 1×6 | 2×6 4×6 |
6x 8 4×12 |
6×12 | 8×12 | 12×12 | 24×12 | ||||||||||||
| Outer diameter (mm) | 1.8 | 2.0 | 2.5 | 2.5 | 2.5 | 2.5 | |||||||||||||
| Adjustable (OEM) | 1.5|2.0 | 1.8|2.3 | 2.1|2.3 | 2.1|2.3 | 2.1|2.3 | 2.1|2.3 | |||||||||||||
| Central strength member | Material | Glass Fbre Reinforced Plasticrod (GFRP) | |||||||||||||||||
| Diameter (mm) | 2.0 | 2.0 | 2.5 | 2.8 | 3.7 | 2.6 | |||||||||||||
| Adjustable (OEM) | 1.8|2.3 | 1.8|2.3 | 2.5 | 2.8 | 3.7 | 2.6 | |||||||||||||
| PE coated diameter (mm) | No | 4.2 | 7.4 | 4.8 | |||||||||||||||
| Water Blocking | Material | Water blocking tape | |||||||||||||||||
| Peripheral Strength | Material | Aramid Yarn | |||||||||||||||||
| Outer Sheath | Thickness (mm) | 1.8mm(1.5-2.0mm OEM) HDPE | |||||||||||||||||
| Cable diameter(mm) Approx. | 9.5 | 9.5|10 | 12.2 | 13.9 | 17.1 | 20.2 | |||||||||||||
| Cable diameter(mm) Adjustable (OEM) | 8.0|8.5|9.0 | 10.5|11.0 | |||||||||||||||||
| Operating temperature range(℃) | From -40~+70 | ||||||||||||||||||
| Max. span (m) | 80m | 100m | 120m | 200m | 250m | ||||||||||||||||||
| Climate condition | No Ice,25m/s Max Wind Speed | ||||||||||||||||||
| MAT | Design according to customer requirements | ||||||||||||||||||
| √ Other structure and fibre count are also available according to customer requirements. | |||||||||||||||||||
| √ Cable diameter and weight in this table is typical value, which will fluctuate according to different designs | |||||||||||||||||||
| √ The span needs to be recalculated due to other climate conditions according to the installation area. | |||||||||||||||||||
Remarks:
Detail requirements need to be sent to us for cable design and price calculation. Below requirements are a must:
A, Power transmission line voltage level
B, fiber count
C, Span or tensile strength
D, weather conditions
How to Ensure the Quality and Performance of Your Fiber Optic Cable?
We control the products quality from the raw material to the finish produts All the raw material should be tested to match the Rohs standard when they arrived at our manufacture.We control the quality during the producing process by advanced technology and equipments. We test the finished products according to the test standard. Approved by various professional optical and communication product institution , JQ also conduct various in-house testing in its own Laboratory and Test Center. We also conduct test with special arrangement with the Chinese Government Ministry of Quality Supervision & Inspection Center of Optical Communication Products(QSICO).
ADSS Single Jacket All-Dielectric Self-Supporting Fiber optic cable is idea for installation in distribution as well as transmission envirline installations are required as its name indicates, there is no support or messenger wire required, so installation is achieved in a single pass.Structural features:Single layer ,Loose tube stranding, Non-metal strength member, Half dry water-blocking, Aramid yarn strength member, PE outer jacket. Includes 2 core, 4 core, 6 core, 8 core, 12 core, 16 core, 24 core, 36 core, 48 core, 96 core, up to 144 core.
2-144 Core Single Jackets ADSS Cable Specifications:
|
Cable fiber count
|
/
|
2~30
|
32~60
|
62~72
|
96
|
144
|
|
|
Structure
|
/
|
1+5
|
1+5
|
1+6
|
1+8
|
1+12
|
|
|
Fiber style
|
/
|
G.652D
|
|||||
|
Central strength member
|
material
|
mm
|
FRP
|
||||
|
Diameter (average)
|
1.5
|
1.5
|
2.1
|
2.1
|
2.1
|
||
|
Loose Tube
|
Material
|
mm
|
PBT
|
||||
|
Diameter (average)
|
1.8
|
2.1
|
2.1
|
2.1
|
2.1
|
||
|
Thickness(average)
|
0.32
|
0.35
|
0.35
|
0.35
|
0.35
|
||
|
Max fiber/loose tube
|
6
|
12
|
12
|
12
|
12
|
||
|
Tubes color
|
Full color identification
|
||||||
|
Fiber excess length
|
%
|
0.7~0.8
|
|||||
|
Water resistance
|
Material
|
/
|
Cable jelly + water resistant layer
|
||||
|
Non-metallic strengthen components
|
Material
|
/
|
Aramid Yarn
|
||||
|
Outer sheath
|
material
|
mm
|
MDPE
|
||||
|
Outer sheath
|
1.8mm
|
||||||
|
Cable diameter(average)
|
mm
|
9.6
|
10.2
|
10.8
|
12.1
|
15
|
|
|
Cable weight (Approximate)
|
kg/km
|
70
|
80
|
90
|
105
|
125
|
|
|
Cable Sectional area
|
mm2
|
72.38
|
81.72
|
91.61
|
115
|
176.7
|
|
|
Attenuation coefficient(Max)
|
1310nm
|
dB/km
|
0.35
|
||||
|
1550nm
|
0.21
|
||||||
|
Rated Tensile Strength(RTS)
|
kn
|
5.8
|
|||||
|
Max allowed tension( MAT)
|
kn
|
2.2
|
|||||
|
Annual average operating tension (EDS)
|
kn
|
3.0
|
|||||
|
Young’s modulus
|
kn/mm2
|
7.6
|
|||||
|
Coefficient of thermal expansion
|
10-6/℃
|
9.3
|
|||||
|
Crush resistance
|
Long term
|
N/100mm
|
1100
|
||||
|
Short term
|
2200
|
||||||
|
Permission Bent Radius
|
static
|
mm
|
15 of OD
|
||||
|
dynamic
|
20 of OD
|
||||||
|
Temperature
|
When laying
|
℃
|
-20~+60
|
||||
|
Storage and transportation
|
-40~+70
|
||||||
|
runing
|
-40~+70
|
||||||
|
Scope of application
|
Suitable for voltage level under 110kV, wind speed below 25m/s, icing 5mm
|
||||||
|
Cable Marks
|
Company Name ADSS-××B1-PE-100M DL/T 788-2001 ××××M Year
(Or at customer’s request) |
||||||
Note :
Only s part of ADSS cable are listed in the table. ADSS cables with other spans can be inquired from JQ Fiber directly.
Specifications in the table are got on condition that there is no height difference and the installation sag is 1%.
Fiber count is 2 to 144. The identification of fibers complies with the national standard.
This datasheer can only be a rerence, nor a supplement to the contract. Please contact our sales people for more detailed information.